Hebei Sucang Medical Devices Technology Co.,Ltd
Add:N0.8 Dubei Street,Xinhua District,Shijiazhuang,Hebei
Zip Code: 061800
Inter-business department
Telephone:(0311) 68032187
Phone:17731122698
Email:info@sucang-medi.com
DISPOSABLE VINYL GLOVE
-Technique Data
Item |
Test item |
Standard Requirement |
Testing result |
|
1 |
Size |
Width 95mm+/-5mm |
95mm |
|
2 |
Length 230mm +/-10mm |
235mm |
||
3 |
Thickness>=0.05mm |
0.06mm |
||
4 |
Impervious test |
Ac 10 Re 11 |
3 |
|
5 |
Tensile Strength(mPa/N) |
Before aging |
Strength>=11MPA |
11-14MPA |
6 |
After aging |
Strength>=11MPA |
11-13MPA |
|
7 |
elongation(%) |
Before aging |
Elongation>=300% |
320-380% |
8 |
After aging |
Elongation>=300% |
300%-350% |
DISPOSABLE NITRILE GLOVE
-Technique Data
Item |
Test item |
Standard Requirement |
Testing result |
|
1 |
Size |
Width XS 75mm+/-5mm |
95mm |
|
2 |
Width S 85mm+/-5mm |
85mm |
||
3 |
Width M95mm+/-5mm |
95mm |
||
4 |
Width L 105mm+/-5mm |
105mm |
||
|
Width XL 115mm+/-5mm |
115mm |
||
5 |
Length 240mm +/-10mm |
240mm |
||
6 |
Thickness>=0.07mm |
0.06mm |
||
7 |
Impervious test |
Ac 10 Re 11 |
3 |
|
8 |
Tensile Strength(mPa/N) |
Before aging |
Strength>=14MPA |
15MPA |
9 |
After aging |
Strength>=14MPA |
15MPA |
|
10 |
elongation(%) |
Before aging |
Elongation>=500% |
650% |
11 |
After aging |
Elongation>=400% |
550% |
DISPOSABLE MEDICAL MASKS
2. Bacterial Filtration Efficiency
Test Method |
Test Description |
ASTM F2100 |
ASTM F1862 |
Fluid Resistance by synthetic blood,in mm Hg |
120mm Hg |
MIL-M-36954C |
Delta P Differential pressure,mm H2O/cm2 |
<5.0mm H2O |
ASTM F2101 |
Bacterial Filtration Efficiency (BFE),% |
>=95% |
ASTM F2299 |
Submicron Particulate Filtration (PFE)0.1 u % |
>=95% |
16 CFR Part 1610 |
Flammability |
Class1 |
KN95
-Standard:GB2626-2006
-Test datas:
Standard Require |
Actual testing |
Remark |
||
KN95 >=95% Test Air flow filter element (85+/-4) L/min |
No. |
Initial filtration |
Loading filtration |
|
1# |
99.8% |
98.4% |
|
|
2# |
99.7% |
98.4% |
|
|
Environment temperature ( 25+/-5)℃ |
21 ℃ |
|
||
Relative humidity (30+/-10) % |
31 % |
|
||
inhalation resistance 《=350Pa |
3# |
94Pa |
|
|
4# |
94Pa |
|
||
Expiratory resistance 《=250Pa |
3# |
76Pa |
|
|
4# |
76Pa |
|
In order to produce the highest quality gloves and masks, we ensure our manufacturing process and quality control are always meeting the stringent requirements Standard.
Our integrity is very important to us.
Shenning medical is committed to Premium Quality and Strict Standards by keeping up to date on the latest trends in all industries. We take every step to ensure our standards are met by purchasing top quality raw materials for production. Quality assurance is monitored with inspection of raw materials for production, throughout various stages of the manufacturing process, assorted sampling and quality control test are routinely carried out to monitor our operation and product quality. Our gloves are tested for their dimensional requirements of length, width, thickness and their tensile strength. These tests include 1000ml watertight test, air inflation test, chemical residue test and visual inspection. The arrival of products to our warehouse meet more regulatory require-ments to ensure that they meet all our high qualifications.